- What this programme covers — the technology ecosystem
- Neuronavigation & Robotics at KIMS is not a single procedure — it is the technology platform that makes every other neurosurgical procedure more controlled and more effective. The complete ecosystem: (1) StealthStation neuronavigation (GPS for the brain — real-time 3D instrument tracking on the MRI). (2) Stealth AutoGuide robotic cranial guidance (first in India at KIMS — sub-millimetre accuracy for biopsy, sEEG, DBS, shunt, and deep tumour). (3) O-Arm intraoperative 3D CT (corrects for brain shift during large resections, confirms spine screw position). (4) ICG fluorescence angiography (confirms aneurysm clip and AVM resection completeness in real time). (5) 5-ALA fluorescence guidance (makes high-grade glioma cells glow pink — 36% to 65% complete resection). (6) IONM (continuous MEP/SSEP/EMG monitoring throughout every procedure). (7) ECoG + cortical stimulation (direct functional brain mapping during awake craniotomy and epilepsy surgery). (8) Midas Rex + CUSA + endoscopes (the instruments). (9) Frame-based and frameless stereotaxy (full stereotactic capability for all workflows).
- Three fundamental problems these technologies solve
- (1) The invisible boundary: the critical structures — motor cortex, speech areas, visual pathway, cranial nerves, major vessels — are invisible within or beyond the tumour unless actively mapped. Neuronavigation, fluorescence, brain mapping, and IONM all exist to make these boundaries visible. (2) Brain shift: after the skull is opened, the brain moves due to CSF loss, dura retraction, gravity, and tumour removal. Pre-operative MRI becomes progressively less accurate as the operation proceeds. O-Arm intraoperative CT corrects this in real time. (3) The functional margin: where to stop resecting in eloquent cortex. Intraoperative cortical stimulation with the patient awake (or IONM under anaesthesia) defines this boundary to within millimetres for each individual patient.
- Stealth AutoGuide
- The Stealth AutoGuide robotic cranial guidance platform was first deployed in India at KIMS Hospitals Secunderabad. It is a frame-free robotic system that couples to the StealthStation navigation workstation and positions a guide tube at any planned intracranial target with image-guided targeting — without the cumbersome rigid stereotactic head frame that was the previous standard of care for stereotactic procedures. Applications at KIMS: stereotactic biopsy (deep, eloquent, or small lesions), sEEG electrode placement (epilepsy surgery evaluation), DBS lead implantation, navigated VP shunt placement, deep-seated tumour resection, laser ablation catheter placement.
- 5-ALA — the fluorescence that changed glioma surgery
- 5-aminolevulinic acid (5-ALA) is an oral agent taken 3 hours before surgery that is converted to a fluorescent compound (protoporphyrin IX) inside high-grade glioma cells. Under violet-blue light in the operating microscope, glioma cells glow pink-red while normal brain remains non-fluorescent. This makes the tumour margin visible at the cellular level — where it was invisible under white light. Clinical impact: the pivotal trial (Stummer et al., Lancet Oncology 2006) demonstrated an increase in complete GBM resection from 36% without 5-ALA to 65% with 5-ALA. Used for every high-grade glioma operation at KIMS.
- Which programmes use these technologies — cross-reference guide
- Brain Tumour Surgery: StealthStation + 5-ALA + ICG + IONM + Stealth AutoGuide for biopsy + O-Arm for brain shift + CUSA + operating microscope for all tumour cases. Functional Neurosurgery: Stealth AutoGuide for sEEG (epilepsy) + DBS lead placement + ECoG for epilepsy onset-zone localisation + O-Arm for asleep DBS. MRgFUS: complements this ecosystem as the non-invasive alternative for tremor (no navigated instruments needed). Spine Surgery: O-Arm navigated pedicle screws + StealthStation for MISS.
- Contact and access
- 040-44885000 (outpatient, no referral required) · 040-46324365 (24×7 emergency) · neuroscience@kimshospitals.com · The Neuronavigation and Robotics technologies are deployed automatically for all complex neurosurgical cases at KIMS — patients do not need to specifically request them.
| Fact | Details |
|---|---|
| 9 technologies | StealthStation navigation · Stealth AutoGuide robotic · O-Arm 3D intraoperative CT · ICG fluorescence angiography · 5-ALA fluorescence (36%→65% GBM) · IONM (MEP/SSEP/EMG) · ECoG + cortical stimulation · Midas Rex + CUSA + endoscopes · Frame-based + frameless stereotaxy |
| 3 problems solved | Invisible boundaries (navigation + fluorescence + mapping) · Brain shift (O-Arm real-time CT update) · Eloquent cortex boundary (cortical stimulation + IONM) |
| Cross-programme links | Brain Tumour Surgery: StealthStation + 5-ALA + ICG + IONM + biopsy · Functional Neurosurgery: sEEG + DBS + ECoG · Spine Surgery: O-Arm navigated screws |
| First-in-India | Stealth AutoGuide robotic cranial guidance · First deployed at KIMS Hospitals Secunderabad · for cranial procedures |
| Contact | 040-44885000 (outpatient) · 040-46324365 (24×7 emergency) · Deployed automatically for all complex cases at KIMS |
Stealth AutoGuide™ Robotic Cranial Guidance Platform at KIMS Hyderabad
KIMS Hospitals Secunderabad was the first hospital in India to perform cranial procedures using the Stealth AutoGuide™ Robotic Guidance Platform — a frame-free robotic system that positions surgical instruments at image-guided targeting for biopsies, depth electrode implantation, tumour resection, and shunt placement. Combined with the StealthStation™ navigation system and Midas Rex™ high-speed drilling technology, KIMS operates the most integrated robotic cranial guidance ecosystem in South India.
What Neuronavigation Is
Neuronavigation is a real-time surgical guidance system that merges the patient's pre-operative MRI or CT images with the physical operating field, creating a live three-dimensional map that allows the surgeon to see precisely where every instrument is positioned relative to brain structures at every moment of the surgery — like GPS for the inside of the skull.
Neuronavigation and Robotic-Guided Brain Surgery at KIMS — Navigation, Intraoperative Imaging and Robotic Guidance
Modern brain and spine surgery is no longer performed by feel, estimation, or anatomical assumption alone. At KIMS Hyderabad, every complex neurosurgical case is supported by a layered system of guidance and safety technologies: navigation systems that show the surgeon where they are in the brain in real time; a robotic guidance platform that positions instruments at the planned target that no freehand technique can replicate; intraoperative imaging that updates the surgical map when the brain shifts during the operation; electrophysiological monitoring that sounds an alarm before a nerve is damaged; and brain mapping tools that define the boundaries of eloquent cortex before a single cut is made. These technologies do not replace surgical skill — they amplify it, systematically removing the sources of error and uncertainty that have historically made brain surgery more dangerous than it needs to be.
KIMS Hyderabad uses the Stealth AutoGuide robotic cranial guidance platform for selected stereotactic procedures. This, combined with the full neuronavigation, O-Arm, brain mapping, and intraoperative monitoring infrastructure, constitutes the most comprehensive surgical guidance ecosystem available in Telangana and Andhra Pradesh.
The Full Technology Inventory at KIMS Neurosurgery
StealthStation™ Neuronavigation
Real-time GPS for the brain — merges the pre-operative MRI with the patient's anatomy on the operating table. Continuous tracking of every instrument on triplanar MRI views during the operation.
Stealth AutoGuide™ —
Frame-free robotic cranial guidance platform. Positions a surgical guide tube to any intracranial target with sub-millimetre accuracy — for biopsy, sEEG, deep-seated tumour resection, and shunt placement.
O-Arm® Intraoperative 2D/3D Imaging
Mobile flat-panel imaging that acquires a full 3D CT volume in a single 360° rotation. Fuses automatically with StealthStation to correct for brain shift and confirm pedicle screw position before closure.
Operating Microscope with ICG Angiography
Indocyanine green fluorescence angiography integrated into the operating microscope — for real-time vessel patency verification in aneurysm clipping, AVM resection, and bypass surgery.
Operating Microscope with 5-ALA Fluorescence
5-aminolevulinic acid fluorescence guidance for high-grade glioma resection. Under violet-blue light, tumour cells glow pink-red against normal brain — improving complete resection rates from 36% to 65% (Stummer Lancet Oncology 2006).
Intraoperative Nerve Monitoring (IONM)
Continuous monitoring of motor evoked potentials (MEP), somatosensory evoked potentials (SSEP), and free-running EMG of cranial nerves — sounds an alarm before a pathway is damaged.
Intraoperative ECoG + Cortical Stimulation
Electrocorticography grids and bipolar cortical stimulation for awake mapping of eloquent cortex — used routinely in awake craniotomy for speech and motor mapping and in epilepsy surgery for ictal-onset-zone localisation.
Midas Rex™ Drill · CUSA · Neuroendoscopes
Midas Rex™ high-speed surgical drill, CUSA ultrasonic aspirator for tumour debulking without traction injury, and rigid + flexible neuroendoscopes for transsphenoidal pituitary surgery and intraventricular procedures.
Stereotaxy — Frame-Based & Frameless
Full stereotactic capability including the traditional Leksell rigid frame and the modern frame-free Stealth AutoGuide robotic alternative — providing flexibility across biopsy, sEEG, and DBS workflows.
The Problem They Solve
Neuronavigation, robotic guidance, intraoperative imaging, fluorescence, and continuous monitoring exist because brain surgery faces three persistent problems that no operating microscope can solve alone.
The fundamental surgical challenge: seeing what you cannot see
The brain is enclosed in solid bone. The critical structures that must be protected — the motor cortex, the speech areas, the visual pathway, the cranial nerves, the major arteries and veins — are invisible to the surgeon unless they are directly exposed in the surgical field. Even within the surgical field, the boundary between tumour and normal brain, between malignant infiltrating glioma and functioning eloquent cortex, is not visible to the naked eye or even under the operating microscope without additional guidance. Neuronavigation, intraoperative imaging, brain mapping, fluorescence guidance, and robotic targeting all exist to solve one problem: making the invisible visible, so that the surgeon can operate at the limits of anatomical tolerance with the maximum possible safety margin.
Brain shift: why pre-operative images alone are not sufficient
When the skull is opened and surgery begins, the brain physically moves within the skull. CSF drains out through the opening, the brain loses support, and the dura retracts. Tumour removal creates a cavity. The effect of gravity changes as the patient is repositioned. This movement — called brain shift — means that the pre-operative MRI, however detailed, gradually loses accuracy as a surgical guide as the operation progresses. By 30–60 minutes into surgery, the brain may have shifted several millimetres from its pre-operative position, making neuronavigation based on the original MRI increasingly unreliable. The O-Arm intraoperative imaging system at KIMS addresses this by providing a real-time CT update of the surgical anatomy during the operation — correcting for brain shift and restoring navigational accuracy.
Eloquent cortex and the functional boundary: the margin between resection and deficit
The most critical decision in tumour surgery near eloquent cortex is where to stop resecting. The boundary between tumour and functional brain is not a clean anatomical line. Infiltrating gliomas invade functioning brain tissue — the tumour cells and the functional neurons coexist in the same tissue volume. Removing this tissue removes tumour cells but also causes neurological deficit. Leaving it preserves function but leaves tumour behind. Determining where this functional boundary lies — exactly, for each individual patient — is what intraoperative cortical stimulation mapping and continuous neurophysiological monitoring achieve at KIMS.
Guidance Capability & Decision Factors
Guidance Capability
Stealth AutoGuide™ Robotic Cranial Guidance
StealthStation™ navigation + Midas Rex™ + O-Arm integration
5-ALA fluorescence and ICG angiography microscopy
MEP, SSEP, and cranial-nerve EMG monitoring
Intraoperative ECoG and cortical stimulation mapping
Frame-based stereotaxy when the workflow requires it
Decision Factors
Tumour or target depth and proximity to eloquent cortex
Brain-shift risk and need for intraoperative imaging update
Need for tissue diagnosis vs maximal safe resection
Vascular anatomy and need for ICG verification
Multidisciplinary tumour board / cerebrovascular conference consensus
Sub-Pages in This Section
Real-Time Brain Mapping
How KIMS maps the brain before and during surgery using fMRI, DTI tractography, StealthStation neuronavigation, O-Arm intraoperative imaging, awake cortical stimulation, intraoperative ECoG, and continuous neurophysiological monitoring. How these tools work together to protect eloquent cortex, white matter tracts, and cranial nerves during complex surgery.
View DetailsRobotic Assist in Brain and Spine Surgery
The Stealth AutoGuide™ robotic cranial guidance platform: what it is, how it works, and what procedures it enables. Clinical outcomes at KIMS: biopsy, sEEG electrode placement, deep-seated tumour resection, shunt placement. O-Arm navigated pedicle screw placement and minimally invasive spine applications. How robotics changes the risk and guidance profile of complex procedures.
View Details