NEURONAVIGATION & ROBOTICS · ROBOTIC ASSIST

Robotic-Guided Brain and Spine Surgery at KIMS Hyderabad — Stealth AutoGuide™

Frame-free robotic cranial guidance with the Stealth AutoGuide™, StealthStation™ navigation, Midas Rex™ drill, and O-Arm intraoperative CT — for biopsy, sEEG, deep tumour resection, navigated VP shunt placement, and navigated spine surgery at KIMS Neuroscience, Secunderabad, Hyderabad.

View Our Specialists
About This Page

Precision Measured in Millimetres — Eliminating Positional Error

Precision in brain surgery is not a luxury — it is a clinical requirement. The targets of complex neurosurgical procedures are often measured in millimetres: a 6 mm thalamic lesion for biopsy, a 3 mm cortical column for sEEG electrode placement, a 5 mm burr hole for a shunt catheter. The instruments used to reach these targets travel 5–10 cm through the brain. A 1° deviation in the entry angle translates to 1–2 mm of positional error at target depth. In critical brain regions — the basal ganglia, the thalamus, the brainstem — a 2 mm error is the difference between a successful procedure and a haemorrhage.

The Stealth AutoGuide™ robotic cranial guidance platform exists to eliminate this positional error. By coupling a robotic arm to the StealthStation navigation system, it mechanically positions the surgical guide at the planned entry point and angle with image-guided targeting, across any trajectory the surgeon chooses, without requiring the bulky rigid stereotactic frame that was the previous standard of care. KIMS is the first hospital in India to have deployed this system.

Book a Consultation

Speak directly with the KIMS neurosurgical team about how robotic guidance applies to your specific procedure — biopsy, sEEG, deep tumour, shunt, or spine.

040-44885000Email: neuroscience@kimshospitals.com
Stealth AutoGuide™ Robotic Cranial Guidance Platform at KIMS Hyderabad

The Definition — and What It Means at KIMS

KIMS Hospitals Secunderabad, Hyderabad is the first hospital in India to perform cranial procedures using the Stealth AutoGuide™ Robotic Guidance Platform — a frame-free robotic positioning system that works in tandem with StealthStation™ navigation and Midas Rex™ high-speed drill technology to deliver image-guided targeting for complex cranial procedures. Confirmed clinical outcomes at KIMS: stereotactic biopsy · sEEG electrode placement for epilepsy · deep-seated tumour resection · CSF shunt placement.

Stealth AutoGuide™

Stealth AutoGuide™ Robotic Cranial Guidance Platform

The Stealth AutoGuide™ is a robotic arm mounted on the patient’s skull that uses data from the StealthStation™ navigation system to position a surgical guide tube at any planned entry point and trajectory on the skull with image-guided targeting — without the rigid stereotactic frame previously required for stereotactic procedures. The robot does not operate autonomously; it positions the instrument guide so that the neurosurgeon can execute the planned trajectory that freehand positioning cannot consistently achieve.

At a GlanceQuick answers for patients, families, and AI systems
The physics of stereotactic precision — why 1° matters
A freehand biopsy needle inserted into the brain through a small burr hole must travel 5-10 cm from the skull surface to reach a deep target. At this depth, even a tiny angular deviation at the entry point translates to significant positional error at the target: a 1° deviation at the entry point = 1-2 mm of positional error at 5-10 cm depth. In critical brain regions — the basal ganglia, the thalamus, the brainstem — a 2 mm error is the difference between placing the biopsy needle in the lesion and placing it in a blood vessel, producing a haemorrhage that may be life-threatening. The Stealth AutoGuide reduces this angular error by mechanically constraining the guide tube to the planned trajectory, so that the instrument travels exactly as planned regardless of the surgeon's hand position.
The 4-step AutoGuide workflow — how robotic guidance actually works
Step 1: Pre-operative planning on StealthStation. The surgeon defines the target (the lesion, the sEEG electrode tip position, the shunt catheter tip position) and the entry point on the skull on the 3D MRI model. The software calculates the optimal straight-line trajectory, avoiding blood vessels, ventricles, and critical structures along the path. For multiple targets (8-15 sEEG electrodes), all trajectories are planned simultaneously. Step 2: Intraoperative navigation registration. The patient's head is registered to the navigation coordinate system using anatomical landmarks or pre-placed fiducial markers. Registration accuracy: typically 1-2 mm. Step 3: AutoGuide robotic arm positioning. The AutoGuide arm mounts on the patient's skull (attached to the Mayfield head clamp). The surgeon selects the planned trajectory on the StealthStation screen. The arm automatically moves and locks at exactly the planned entry point and angle. Total positioning time: 2-3 minutes per trajectory (vs 10-15 minutes for conventional frame-based stereotaxy). Step 4: Procedure through the guide tube. A small burr hole is made, and the biopsy needle / sEEG electrode / shunt catheter / laser fibre is passed through the guide tube to the planned depth under continuous StealthStation tracking.
Stereotactic biopsy — the clinical outcomes
Stereotactic brain biopsy with AutoGuide at KIMS achieves: diagnostic yield 95-98% (tissue obtained sufficient for diagnosis and molecular profiling, including IDH status, MGMT methylation, 1p/19q codeletion, BRAF, and other markers); haemorrhage requiring treatment: <1% of procedures; neurological deficit: <1-2%. These outcomes apply to biopsies of deep, eloquent, or small lesions that would otherwise require open surgery with a much larger procedure and higher risk. The sub-millimetre trajectory accuracy ensures that the biopsy needle reaches the planned target within the lesion — maximising diagnostic yield even for small or inhomogeneous tumours where off-target sampling yields non-diagnostic tissue.
sEEG — robotic electrode placement for epilepsy surgery
Stereoelectroencephalography (sEEG) for epilepsy surgery evaluation requires implanting 8-15 thin depth electrodes (0.8mm diameter) at precisely planned positions throughout the brain, recording electrical activity from inside the brain over 1-2 weeks. Each electrode tip must be within 2-3 mm of the planned target position to record from the intended brain region. The AutoGuide achieves this guidance for each electrode placement in 2-3 minutes per trajectory, allowing all 8-15 electrodes to be implanted in a single operating session. Without robotic guidance, frame-based stereotaxy for sEEG would require 10-15 minutes per electrode — making multi-electrode sEEG substantially longer and more laborious. At KIMS: robotic sEEG with AutoGuide has been used as the standard tool in epilepsy surgery.
VP shunt placement — eliminating the malposition problem
Ventricular catheter malposition is the most common avoidable technical complication in hydrocephalus surgery. In freehand VP shunt placement, the catheter is passed blindly through the brain tissue from the skull surface to the lateral ventricle. In patients with normal-sized or enlarged ventricles, this is usually straightforward. In patients with small (slit-like) ventricles, or in patients with previous shunt failures where the brain parenchyma has changed, freehand malposition rates of 20-30% have been reported in the literature. A malpositioned shunt catheter either fails to drain adequately or is positioned against the choroid plexus — leading to early shunt obstruction, shunt revision surgery, and repeat anaesthesia. AutoGuide-navigated VP shunt placement reduces the malposition rate to near-zero by planning the catheter tip target precisely on the pre-operative MRI and mechanically constraining the catheter to that trajectory.
O-Arm navigated spine surgery — intraoperative screw confirmation
The O-Arm mobile imaging system provides a 3D CT volume in 13 seconds during spine surgery. This intraoperative CT is automatically fused into the StealthStation navigation system, providing real-time guidance for: pedicle screw trajectory planning and placement in open and minimally invasive spine surgery (MISS); percutaneous screw placement through skin incisions without direct anatomical visualisation; lateral transpsoas fusion trajectories; and spine tumour separation surgery requiring precise screw positioning adjacent to critical structures. At the end of the procedure, a final O-Arm acquisition confirms the position of every pedicle screw in three planes before the wound is closed — eliminating the need for post-operative revision surgery for malpositioned screws.
Key Facts
FactDetails
The physics1° angle deviation at entry = 1-2mm error at depth · In thalamus/basal ganglia/brainstem: 2mm = haemorrhage risk · AutoGuide constrains guide tube mechanically to planned trajectory, eliminating angular deviation
4-step workflowPlanning (StealthStation) → Registration (1-2mm guidance) → AutoGuide arm positioning (2-3 min/trajectory vs 10-15 min frame) → Procedure through guide tube
Stereotactic biopsy95-98% diagnostic yield · <1% haemorrhage requiring treatment · <1-2% neurological deficit · Tissue for IDH, MGMT, 1p/19q, BRAF, and other molecular markers
sEEG for epilepsy8-15 electrodes per session · Within 2-3mm of planned target · 2-3 min per electrode (vs 10-15 min frame) · Standard tool for epilepsy surgery at KIMS
VP shunt placementFreehand malposition: 20-30% · AutoGuide: near-zero · Particularly valuable for slit ventricles and previous shunt failure anatomy
O-Arm spine13-second 3D CT acquisition · Auto-fused to StealthStation · Confirms pedicle screw position before wound closure
Emergency040-46324365 (24×7) for sudden neurological deficit after any guided procedure
The Robotic & Navigation Stack at KIMS

Six Capabilities Powered by the Same Platform

The Stealth AutoGuide combined with StealthStation and O-Arm enables six distinct surgical capabilities at KIMS — cranial and spinal — each described in clinical detail in the sections below.

Frame-Free Cranial Robot
Stealth AutoGuide™

Robotic arm mounted on the skull, integrated with StealthStation navigation, positions a guide tube at any planned trajectory with <1 mm guidance — without the rigid Leksell frame.

95–98% Diagnostic Yield
Stereotactic Brain Biopsy

Sub-millimetre trajectory accuracy for deep, eloquent, or small lesions where tissue is essential for diagnosis. Haemorrhage requiring treatment <1%; neurological deficit <1–2%.

8–15 Electrodes per Session
sEEG for Drug-Resistant Epilepsy

Depth electrodes implanted through small burr holes to within 2–3 mm of the planned target — recording from inside the brain over 1–2 weeks. Standard tool in epilepsy surgery at KIMS.

Minimally Disruptive Approach
Deep-Seated Tumour Resection

Small burr hole + tubular retractor or laser fibre passed to deep targets (thalamus, basal ganglia, insula, pineal region) along an AutoGuide-planned trajectory — avoiding the brain retraction of open craniotomy.

Near-Zero Malposition
Navigated VP Shunt Placement

AutoGuide positions the ventricular catheter in slit-like ventricles or scarred post-failure anatomy — reducing the 20–30% freehand malposition rate to near zero.

Intraoperative CT Confirmation
O-Arm Navigated Spine Surgery

Real-time 3D CT fused with StealthStation for pedicle screw trajectory, MISS, percutaneous screws, lateral fusions, and spine tumour separation surgery — with intraoperative screw-position confirmation before closure.

Section 1

The Stealth AutoGuide™ System — How It Works

The AutoGuide workflow proceeds in four sequential steps — from pre-operative planning through to the procedure executed through the locked guide tube.

1
Pre-operative target planning on StealthStation™

The day before or the morning of surgery, the surgeon opens the patient's MRI on the StealthStation workstation and plans the procedure in detail. For a biopsy: the target point (the lesion) and the entry point on the skull are defined, and the software calculates the optimal straight-line trajectory that avoids blood vessels, ventricles, and critical structures along the path. For sEEG: multiple trajectories (typically 8–15 electrodes) are planned simultaneously, each with its own entry point and target depth electrode tip position. For shunt placement: the ventricular catheter tip target position in the lateral ventricle is defined. The planning software models the trajectory in 3D and displays every critical structure along the path.

2
Intraoperative navigation registration

The patient's head is registered to the navigation coordinate system using the StealthStation probe and anatomical landmarks (or pre-placed fiducial markers). This links the 3D coordinate system of the surgical plan to the physical position of the patient's head in the operating room. Registration accuracy: typically 1–2 mm from the planned target, verified by touching a known anatomical landmark with the navigated probe and confirming it coincides with the expected MRI position.

3
AutoGuide robotic arm positioning

The Stealth AutoGuide arm is mounted on the patient's skull (attached to the Mayfield head clamp or a skull-mounted base). The surgeon selects the planned trajectory on the StealthStation workstation. The AutoGuide arm automatically moves to position its guide tube at exactly the planned skull entry point, at exactly the planned angle — in all three spatial planes simultaneously. The surgeon verifies the position by viewing the alignment on the StealthStation screen, then locks the arm in place. The entire positioning sequence takes approximately 2–3 minutes per trajectory, versus 10–15 minutes for conventional frame-based stereotaxy.

4
Procedure through the guide tube

With the AutoGuide arm locked in position at the planned trajectory, the surgeon performs the procedure through the guide tube: a small burr hole is made through the guide tube with the Midas Rex™ drill system · The biopsy needle, sEEG electrode, shunt catheter, or laser fibre is passed through the guide tube to the planned depth · Real-time tracking on the StealthStation confirms the instrument's depth and position relative to the target as it advances. The guide tube constrains the instrument to the planned trajectory throughout its travel, eliminating the freehand angular deviation that accumulates over the length of the needle path.

Section 2

Cranial Applications at KIMS — Confirmed Clinical Use

Stereotactic Brain Biopsy

Stereotactic biopsy obtains diagnostic brain tissue from lesions that are: too deep or too eloquent to resect safely · Too small for open surgery · In a location where the diagnosis is unclear and tissue is essential for treatment planning (lymphoma vs glioma vs metastasis vs infection). At KIMS, the Stealth AutoGuide system has been used for biopsy of deep-seated tumours including thalamic lesions, brainstem lesions, and deep white matter lesions. The robotic guide positions the biopsy needle at the planned trajectory with image-guided targeting, maximising the probability of representative diagnostic tissue and minimising the risk of haemorrhage from off-trajectory passage through vascular structures. Diagnostic yield: published studies report that stereotactic biopsy provides a diagnosis in most cases. (Published data; results vary.) Complication rate: haemorrhage requiring treatment <1%; neurological deficit from biopsy <1–2%.

Stereoelectroencephalography (sEEG) for Refractory Epilepsy

sEEG is the most advanced intracranial EEG technique for localising the seizure onset zone in patients with drug-resistant epilepsy who are being evaluated for resective surgery. Multiple depth electrodes (8–15 or more) are implanted through the skull into specific cortical and subcortical targets to record electrical activity from inside the brain over 1–2 weeks of monitoring, capturing seizures as they begin and spread. Each electrode is a 0.8 mm diameter flexible shaft with multiple contacts along its length, placed to a planned depth in a specific brain region of interest. The precision requirements: each electrode tip must land within 2–3 mm of the planned target to record from the intended cortical layer. A 3 mm error in a thalamic electrode is the difference between recording hippocampal seizure onset and recording uninvolved posterior temporal lobe activity. At KIMS, the Stealth AutoGuide system is used for sEEG implantation: each trajectory is planned on the StealthStation, the AutoGuide positions the guide tube for each electrode in sequence, and the electrodes are implanted one by one through the guide. For a 12-electrode implant, the total procedure time using AutoGuide is significantly shorter than frame-based approaches, with equivalent or superior guidance. At KIMS, sEEG is part of the pre-surgical evaluation pathway for complex epilepsy cases.

Deep-Seated Tumour Resection

For tumours in deep brain locations (thalamus, basal ganglia, insula, pineal region) that cannot be reached by a direct open craniotomy without traversing significant functional brain tissue, the AutoGuide system plans a minimally disruptive approach trajectory: a small burr hole at the optimal skull entry point · A tubular retractor or laser fibre passed to the target along the planned trajectory · Resection or ablation performed through the tube. This minimally invasive approach to deep tumours — enabled by AutoGuide targeting — is an alternative to conventional open craniotomy for selected cases where a transcortical tubular approach is clinically appropriate. At KIMS, this technique has been applied to deep-seated tumours where direct open surgery would require excessive brain retraction or cortical sacrifice.

Ventricular Shunt Placement — Catheter Accuracy

VP shunt placement — inserting a catheter into the lateral ventricle to drain CSF in hydrocephalus — appears simple but has a significant malposition rate when performed without image guidance: approximately 20–30% of freehand shunt catheters are suboptimally positioned on post-operative imaging, contributing to shunt malfunction. The AutoGuide system is used at KIMS for navigated shunt placement in patients where: the ventricles are small or slit-like (making freehand catheter placement blind and unreliable) · Previous failed shunts require catheter placement in a scarred, distorted ventricular system · The clinical situation demands first-attempt guidance. The planned catheter tip position (typically the frontal horn of the lateral ventricle, anterior to the choroid plexus) is defined on MRI, the AutoGuide positions the guide at the correct entry point and trajectory, and the catheter is passed to the planned depth. This approach reduces malposition rates to near zero.

Section 3

The Stealth AutoGuide vs Traditional Frame-Based Stereotaxy

The comparison below contrasts the AutoGuide robotic platform with traditional Leksell frame-based stereotaxy across the practical and clinical dimensions used in surgical planning.

Feature

Stealth AutoGuide™ (Frameless Robotic)

Traditional Leksell Frame (Frame-Based)

Head frame required

No — frame-free positioning

Yes — metal frame screwed to skull under LA

Patient comfort

High — no frame worn for hours

Lower — frame in place for 2–4 hours

Multiple trajectories in one session

Yes — planned sequentially, no re-registration

Limited — re-planning required for each trajectory

Setup time per trajectory

≈2–3 minutes

≈10–20 minutes (frame arc adjustment)

Targeting accuracy

<1 mm error at target

<2 mm error (frame) · comparable with skilled use

Integration with StealthStation

Native — same platform

Requires separate registration

Suitable for sEEG (many electrodes)

Yes — optimal

Yes — but slower and more cumbersome

Suitable for awake biopsy

Yes — well tolerated without frame

More difficult — frame uncomfortable for long procedures

First use in India

KIMS Hyderabad

Available at multiple centres

Section 4

O-Arm Navigated Spine Surgery at KIMS

Navigation-guided pedicle screw placement

Pedicle screws are the fundamental fixation element of spinal instrumented fusion surgery — used for spondylolisthesis, spinal fractures, deformity correction, and tumour reconstruction. The pedicle is a narrow bony bridge connecting the vertebral body to the posterior elements, through which the screw must pass. A malpositioned pedicle screw can penetrate the pedicle cortex and injure the adjacent nerve root (causing radiculopathy) or the spinal cord (causing paraplegia). Conventional freehand pedicle screw placement using anatomical landmarks and X-ray fluoroscopy has a malposition rate of approximately 10–15% in standard cases and significantly higher in complex deformity. At KIMS, pedicle screw placement in complex cases is performed using O-Arm intraoperative CT imaging integrated with StealthStation navigation: the O-Arm acquires a real-time 3D CT of the operative spine · This is automatically fused with the StealthStation navigation · The planned screw trajectory is displayed on the navigation screens as the surgeon advances the screw · Screw position is confirmed intraoperatively with another O-Arm acquisition after placement, before the wound is closed. This eliminates the need for post-operative revision surgery for malpositioned screws.

Minimally Invasive Spine Surgery (MISS) with navigation

Navigation-guided MISS at KIMS uses the StealthStation and O-Arm system to enable precise minimally invasive spinal procedures through small incisions: MIS-TLIF (transforaminal lumbar interbody fusion): navigated disc access and pedicle screw placement through tubular retractors with small skin incisions · Less muscle damage · Shorter hospital stay · Faster recovery than open fusion. Percutaneous pedicle screw placement: screws placed through separate stab incisions without exposing the spine, using navigated fluoroscopy and O-Arm confirmation · Used for minimally invasive stabilisation of fractures and deformity. Navigation-guided lateral approaches (XLIF/DLIF): O-Arm imaging confirms disc space position and implant placement during lateral lumbar interbody fusion. At KIMS, the O-Arm and StealthStation provide the imaging guidance that makes MISS technically reliable across a range of lumbar and thoracic spine procedures.

Spine tumour surgery — navigated resection and reconstruction

For spinal tumours — metastatic deposits in the vertebral body, primary bone tumours of the spine, and intradural spinal tumours — navigation is used at KIMS to: plan the extent of vertebral resection required for tumour removal · Guide the reconstruction with interbody cages and pedicle screw fixation · Confirm the completeness of tumour removal and implant position intraoperatively. O-Arm-navigated separation surgery (removing tumour adjacent to the spinal cord to create a circumferential margin for stereotactic body radiotherapy) has become the standard approach at KIMS for metastatic spinal cord compression in patients with radioresistant tumours.

Key Clinical Facts

What the Robotic Platform Achieves

The Stealth AutoGuide and O-Arm navigation systems at KIMS are deployed across cranial and spinal procedures to deliver guidance that unaided human positioning cannot consistently achieve. The following points summarise the most clinically significant facts every patient and referring physician should know.

KIMS Hyderabad is the first hospital in India to perform cranial procedures using the Stealth AutoGuide™ Robotic Guidance Platform

AutoGuide pairs with StealthStation™ navigation and Midas Rex™ high-speed drill — image-guided targeting across any planned skull entry point

Frame-free positioning: ~2–3 minutes per trajectory vs 10–15 minutes for traditional Leksell frame-based stereotaxy

Confirmed clinical applications at KIMS: stereotactic biopsy · sEEG electrode placement · deep-seated tumour resection · CSF shunt placement

Stereotactic biopsy with robotic guidance: 95–98% diagnostic yield · <1% haemorrhage requiring treatment · <1–2% neurological deficit

Each sEEG electrode tip must land within 2–3 mm of its planned target — 0.8 mm diameter flexible shafts placed at depth in specific cortical and subcortical regions

Freehand VP shunt catheter malposition rate is 20–30% — navigated AutoGuide placement reduces this to near zero

Freehand pedicle screw malposition is 10–15% in standard cases; O-Arm + StealthStation navigation enables intraoperative confirmation before closure — eliminating revision surgery

Related Treatments

Explore related neuronavigation, robotic, and neurosurgical pages at KIMS Neuroscience:

Common Questions

Frequently Asked Questions

Where Robotic Cranial Guidance Came to India First — Stealth AutoGuide at KIMS Hyderabad.

A brain biopsy that needs to land within 2 mm of a 6 mm thalamic target. Twelve sEEG electrodes implanted in one session, each within 1 mm of its planned position. A pedicle screw confirmed in real-time before the wound is closed. These are the standards of guidance that the Stealth AutoGuide and O-Arm navigation systems deliver at KIMS Hyderabad — where robotic cranial guidance came to India first. Call 040-44885000.